Broomfield Colorado Roofing Codes

Broomfield Colorado Roofing Codes

Here are the Broomfield Colorado roofing codes. The current energy code is based on 2015 criteria. There is a manufacturer wind warranty requirement for all Broomfield roof replacements.


Information Updated On

1-15-20


Building Department Phone

303.438.6370


Inspection Line

303.438-6376


Permits

303.438.6370


Fax

303.438.6207


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website


Current Building Code

2015 IBC/IRC


Current Energy Code

2015 IECC


Requires a Building Permit

Yes


Roof System/Fire Rating required for Residential Dwellings

Class C


Roof System/Fire Rating required for Commercial Buildings

Class C


Roof System/Fire Rating required for Multi-Family

Class C


Minimum sustained wind speed rating for Asphalt Shingles

110 MPH 3 second gusts


ASTM Standard for wind rating

D 3161 class F or D 7158 Class H or G


Requires a manufacturer’s wind warranty

Per manufacturer


Requires wind nailing

Yes


Inspectors carry ladders for the final

No


Requires midroof (in progress) inspection

A mid-roof affidavit is required. A mid-roof inspection can be requested in lieu of this document.


Maximum number of layers of asphalt shingles permitted

One


Maximum number of layers of flat roof material permitted

One


Require a sheathing/decking inspection

No


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Minimum gap size for sheeting

¼” gap


Requires drip edge

Yes


Drip edge size minimum

2 x 4


Requires Rake/Gable metal edging

Yes


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required 2:12 up to 4:12

Double layer of 15# with 19” overlap


Underlayment required for 4:12 and above

Single layer of 15#


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

Either


Valley Underlayment/Material required for open valleys

Either


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

4”


Requires ridge cap

Yes


Requires ventilation to meet building codes

Yes


Requires Soffit eave/vents

Yes, on new construction only