Here are the Arvada Colorado roofing codes. There is a requirement for wind nailing on roofs in Arvada, and there is a minimum sustained wind speed rating on asphalt shingles that differs for properties on the east vs. west side of Highway 93.
Information Updated On
1-15-20
Building Department Phone
720.898.7620
Inspection Line
720.898.7630
Please check Codes Locally as some codes may have changed since this page was last updated
Current Building Code
2015 IBC
Requires a Building Permit
Yes
Other/Special Permits required
Complete re-decking requires a separate permit
Roof System/Fire Rating required for Residential Dwellings
Class C
Roof System/Fire Rating required for Commercial Buildings
Class A
Roof System/Fire Rating required for Multi-Family
Class A
Special conditions
Residential shakes are allowed and not a rated system
Minimum sustained wind speed rating for Asphalt Shingles
East of Highway 93 – 136 Vult
West of Highway 93 – 142 Vult
ASTM Standard for wind rating
3161 Class F
Requires a manufacturer’s wind warranty
No
Requires wind nailing
Yes, per manufactures specs, but no less than 4 nails per shingle.
Inspectors carry ladders for the final
Yes, for eave heights less than 12’
Requires midroof (in progress) inspection
For low slope, commercial roofs, and specialty roofs.
Maximum number of layers of asphalt shingles permitted
Two layers
Require a sheathing/decking inspection
Yes
Requires solid sheeting (plywood/OSB) over spaced decking
No
Minimum gap size for sheeting
½”
Requires drip edge
Yes
Drip edge size minimum
Required to cover open areas
Requires Rake/Gable metal edging
Yes
Requires Rake/Gable metal edging
Yes
Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)
No, unless required by the manufacturer
Underlayment required 2:12 up to 4:12
Double underlayment required
Type of valleys allowed
Both
Valley Underlayment/Material required for closed valleys
Bottom layer 1-36” 90 lbs. shingles over top.
Valley Underlayment/Material required for open valleys
Asphalt open valley use 2 layers 90 lbs.
Kick-out required on Step Flashing
Yes
Minimum curb height requirement
Yes, 6 inches
Chimney crickets requirement
Crickets are required for all chimneys and saddles (ridge side) 30” or wider. Existing buildings that are working need not be upgraded.
Requires ridge cap
Yes
Requires ventilation to meet building codes
Yes, per code or per manufacturer
Requires blower door test when increasing ventilation to code
No
Requires Soffit eave/vents
No
Allows 90 lb rolled roofing on low slope heating living space
Allowed in non-heated space only. Not rated for wind but ok for unheated.
Slope
Per manufacturer specifications.