Centennial Colorado Roofing Codes

Centennial Colorado Roofing Codes

These are the specs for the City of Centennial Colorado roofing codes. Note there is a requirement for midroof inspections, and there is a minimum asphalt saturated underlayment requirement.


Information Updated On

1-15-20


Building Department Phone

303-754-3321


Inspection Line

303-754-3321


Fax Line

303-708-1790


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website

Informational Handout


Current Building Code

2015 IRC/IBC


Current Energy Code

2015 IECC


Requires a Building Permit

Yes


Roof System/Fire Rating required for Residential Dwellings

Class A


Minimum sustained wind speed rating for Asphalt Shingles

90 MPH Sustained/110 MPH 3-second gusts


Requires wind nailing

Yes


Inspectors carry ladders for the final

Yes, with one story access


Requires midroof (in progress) inspection

Yes, inspection required at 25% to 75% shingled for concrete, tile, and shake shingle, metal, and flat roofs.


Maximum number of layers of asphalt shingles permitted

Single layer only


Maximum number of layers of flat roof material permitted

Single layer only


Require a sheathing/decking inspection

No


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Minimum gap size for sheeting

½ inch gap


Requires drip edge

No


Requires Rake/Gable metal edging

No


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required 2:12 up to 4:12

Minimum 15-pound asphalt saturated underlayment required. 19-inch laps of underlayment are required, starting with a 19-inch strip and then full sheets.


Underlayment required for 4:12 and above

One layer of 15-pound (minimum) asphalt saturated underlayment required.


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

90 pound


Valley Underlayment/Material required for open valleys

Ice and water under metal


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

No


Chimney crickets requirement

30 inch or greater width


Requires ridge cap

Yes


Requires ventilation to meet building codes

Yes


Requires blower door test when increasing ventilation to code

No


Requires Soffit eave/vents

No


Allows 90 lb rolled roofing on low slope heating living space

Yes


Slope

2:12