Call Us Now! (720) 375-5601
Eagle County Colorado roofing codes are listed below. Minimum sustained wind speed rating for asphalt shingles is 90 MPH with 3 second gusts.
Information Updated On
1-15-20
Building Department Phone
970.328.8730
Inspection Line
1-866-701-3307
Fax
970-328-7185
Please check Codes Locally as some codes may have changed since this page was last updated
Current Building Code
2015 IBC/IRC
Current Energy Code
2015 IECC
Requires a Building Permit
Yes
Roof System/Fire Rating required for Residential Dwellings
Class A
Special conditions
Class of roof system/fire rating is dependent upon specific wildfire hazard for property. Call (970) 328-8742- to obtain a hazard rating.
Minimum sustained wind speed rating for Asphalt Shingles
90 MPH 3 second gusts
Inspectors carry ladders for the final
No
Requires midroof (in progress) inspection
No
Maximum number of layers of asphalt shingles permitted
One layer
Maximum number of layers of flat roof material permitted
One layer
Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)
Yes
Underlayment required for 4:12 and above
Per manufacturer installation instructions and wildfire hazard rating
Requires ventilation to meet building codes
Yes
Permits Soffit eave/vents
Yes