Firestone Colorado Roofing Codes

Firestone Colorado Roofing Codes

These are the Firestone Colorado roofing codes. The current energy code is based on 2009 requirements. The manufacturer wind warranty must meet a 90 MPH minimum.


Information Updated On

1-15-20


Building Department Phone

303-833-3291


Fax Line

303-774-0455


Inspection Line

888-774-0454


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website

Informational Handout


Current Building Code

2012 IRC


Current Energy Code

2009 IECC


Requires a Building Permit

Yes


Roof System/Fire Rating required for Residential Dwellings

Class C


Roof System/Fire Rating required for Commercial Buildings

Class C


Roof System/Fire Rating required for Multi-Family

Class C


Minimum sustained wind speed rating for Asphalt Shingles

90 MPH sustained/110 MPH 3 second gusts


Requires a manufacturer’s wind warranty

Must meet manufacturer rating for 90 MPH


Requires wind nailing

Yes


Inspectors carry ladders for the final

No


Requires midroof (in progress) inspection

No


Maximum number of layers of asphalt shingles permitted

One overlay allowed


Maximum number of layers of flat roof material permitted

One overlay allowed


Require a sheathing/decking inspection

No


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Minimum gap size for sheeting

Any gap at all


Requires drip edge

Yes


Drip edge size minimum

1×2


Requires Rake/Gable metal edging

Yes


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required 2:12 up to 4:12

Double underlayment required


Underlayment required for 4:12 and above

15 pound


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

90 pound


Valley Underlayment/Material required for open valleys

90 pound under metal


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

No


Chimney crickets requirement

24” or greater width


Requires ridge cap

Yes


Requires ventilation to meet building codes
Yes


Requires blower door test when increasing ventilation to code

No


Requires Soffit eave/vents

No


Allows 90 lb rolled roofing on low slope heating living space

Yes


Slope

2:12