Parker Colorado Roofing Codes

Parker Colorado Roofing Codes

Parker Colorado Roofing Codes are provided for homeowners and roofing contractors to do home roof repair and roof replacement. Parker Colorado follows the 2015 standards for building codes and energy codes.


Information Updated On

1-15-20


Building Department Phone

303-841-1970


Inspection Line

303-508-7173


Fax

303-840-8592


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website

Informational Handout


Current Building Code

2015 IRC/IBC


Current Energy Code

2015 IECC


Requires a Building Permit

Yes


Other/Special Permits required

Gutters & siding


Special conditions

Please contact us about the Roof Class Systems


Minimum sustained wind speed rating for Asphalt Shingles

SFD – 115 MPH (90 MPH, 3 second gusts, exposure C): Commercial – please contact


ASTM Standard for wind rating

ASTM D 7158 or ASTMD 3161


Requires wind nailing

Yes, 6 nails per shingle


Inspectors carry ladders for the final

No


Requires midroof (in progress) inspection

Yes, schedule mid-roof day before tear off begins


Maximum number of layers of asphalt shingles permitted

One layer


Maximum number of layers of flat roof material permitted

One layer


Require a sheathing/decking inspection

Yes, if replacing with new sheathing


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Maximum gap size for sheeting

¼ inch gap


Requires drip edge

Yes


Drip edge size minimum

2×2 minimum or large enough to cover any gaps from original construction


Requires Rake/Gable metal edging

Yes


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required 2:12 up to 4:12

19” overlap of 15#


Underlayment required for 4:12 and above

15# manufacture requirements may be more stringent check requirements


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

Either – per manufacture minimum ASTM D 6380 or 1970


Valley Underlayment/Material required for open valleys

Per Manufacture, minimum ASTM D 3909 or 6380 Class M


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

Yes – 4×4


Chimney crickets requirement

30” or greater width – please call for site-specific questions


Requires ridge cap

Yes


Requires ventilation to meet building codes

Yes


Allows 90 lb rolled roofing on low slope heating living space

No, non heated space only