Westminster Colorado Roofing Codes

Westminster Colorado Roofing Codes

Roofing contractors and hail damage roof inspectors can access the Westminster Colorado Roofing Codes for residential roof repair and roof replacement projects as well as commercial roof repair and replacement projects.


Information Updated On

1/6/2019


Building Department Phone

303-658-2075


Inspection Line

303-650-0626


Inspections

Permits


Fax

303-706-3922


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website

Informational Handout


Current Building Code

2015 IRC/IBC


Current Energy Code

2015 IECC


Requires a Building Permit

Yes


Other/Special Permits required

Decking permit


Roof System/Fire Rating required for Residential Dwellings

Class C


Minimum designed wind speed rating for Asphalt Shingles

100-120 MPH, location based


ASTM Standard for wind rating

ASTM D 7158 G or H


Requires a manufacturer’s wind warranty

Per manufacturer


Requires wind nailing

Yes, per manufacturer requirements


Inspectors carry ladders for the final

Yes, with one story access – contractor to provide if over one story


Requires midroof (in progress) inspection

Yes on non-asphalt and commercial builds at 50%


Maximum number of layers of asphalt shingles permitted

One layer


Maximum number of layers of flat roof material permitted

One layer


Require a sheathing/decking inspection

Yes, a decking inspection


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Maximum gap size for sheeting

¼ inch gap


Requires drip edge

Yes


Drip edge size minimum

Must extend ¼ inch below sheathing and 2 inches on roof


Requires Rake/Gable metal edging

Yes


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required for 4:12 and above

15#


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

Either


Valley Underlayment/Material required for open valleys

Either


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

No


Requires positive drainage

Yes


Requires ventilation to meet building codes

Yes, new construction only


Permits Soffit eave/vents

Yes


Allows 90 lb rolled roofing on low slope heating living space

Yes


Low Slope

1:12 per manufacture