Windsor Colorado Roofing Codes

Windsor Colorado Roofing Codes

Homeowners and roofing contractors can review the Windsor Colorado Roofing Codes for residential roof repair and roof replacement projects. Roofing contractors in Windsor also use the roofing codes for commercial roofing.


Information Updated On

1/7/2019


Building Department Phone

970-674-2400


Inspection Line

970-674-1036


Permits


Fax

970-674-2456


Please check Codes Locally as some codes may have changed since this page was last updated

Department Website

Informational Handout


Current Building Code

2012 IRC/IBC


Current Energy Code

2009 IECC


Requires a Building Permit

Yes


Roof System/Fire Rating required for Residential Dwellings

Class A


Special conditions

A,B or C depending on building construction classification


Minimum sustained wind speed rating for Asphalt Shingles

90 MPH 3 second gusts


ASTM Standard for wind rating

ASTM D 7158, ASTM 3161 Class A, D, F


Requires a manufacturer’s wind warranty

Per manufacturer


Requires wind nailing

Yes


Inspectors carry ladders for the final

Yes, with one story access


Requires midroof (in progress) inspection

Yes


Maximum number of layers of asphalt shingles permitted

One layer


Maximum number of layers of flat roof material permitted

One layer


Require a sheathing/decking inspection

Yes – exception: if decking has rotted and been replaced


Requires solid sheeting (plywood/OSB) over spaced decking

Yes


Maximum gap size for sheeting

¼ inch gap


Requires drip edge

Yes


Drip edge size minimum

1 x 2 – cover sheathing by ¼ inch


Requires Rake/Gable metal edging

Yes


Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)

No


Underlayment required 2:12 up to 4:12

19 inch overlap of 15#


Underlayment required for 4:12 and above

15# – for asphalt: two layers on 2:12 – 4:12 non asphalt: varies per code


Type of valleys allowed

Both


Valley Underlayment/Material required for closed valleys

Either


Valley Underlayment/Material required for open valleys

Either


Kick-out required on Step Flashing

Yes


Minimum curb height requirement

No


Chimney crickets requirement

30” or greater width


Requires positive drainage

Yes


Requires ventilation to meet building codes

Yes


Requires Soffit eave/vents

Yes


Allows 90 lb rolled roofing on low slope heating living space

Yes


Low Slope

2:12 – 1:12 allowed but with restrictions